Wearable physiological sensor fusion for pain episode detection: a review

DOI: https://doi.org/10.3846/ntcs.2026.26721

Abstract

Pain episode detection and forecasting from physiological signals collected by wearable devices is becoming increasingly important. Self-reported pain ratings in daily life are recorded irregularly, leaving episode onset, duration, and dynamics incompletely documented. The reviewed literature shows that physiological changes are driven not only by pain but also by movement, emotional arousal, sleep, and environmental factors. Therefore, real-world reliability and false-episode reduction remain key obstacles. This focused review synthesizes clinical and naturalistic use cases, data acquisition strategies, and modeling approaches. These approaches range from feature engineering and classical machine learning to multimodal fusion with attention mechanisms and transformer architectures. Beyond summarizing established findings from the literature, the paper adds two literature-derived synthesis recommendations. The 2 + 1 rule treats at least two physiological signal families plus one context channel as a practical design heuristic for robust wearable pain detection. The KKS principle uses quality indicators and context information to control fusion weights dynamically. Across the reviewed studies, single-signal solutions are frequently vulnerable to signal-quality fluctuations. By contrast, hybrid strategies with explicit quality and context handling show stronger translational potential. However, these recommendations should be interpreted as conceptual guidance requiring further empirical validation, especially across participants, devices, protocols, and uncontrolled daily-life conditions.

Keywords:

pain episode detection, wearable sensors, physiological signals, multimodal fusion, quality control, context-aware modeling, validation
Published in Issue
September 30, 2026
Abstract Views
29

How to Cite

Grubinskienė, A., & Katkevičius, A. (2026). Wearable physiological sensor fusion for pain episode detection: a review. New Trends in Computer Sciences, 4(1), 196–207. https://doi.org/10.3846/ntcs.2026.26721

Share

References

Abd-Elsayed, A., Robinson, C. L., Marshall, Z., Diwan, S., & Peters, T. (2024). Applications of artificial intelligence in pain medicine. Current Pain and Headache Reports, 28(4), 229–238. https://doi.org/10.1007/s11916-024-01224-8

Aqajari, S. A. H., Cao, R., Kasaeyan Naeini, E., Calderon, M.-D., Zheng, K., Dutt, N., Liljeberg, P., Salanterä, S., Nelson, A. M., & Rahmani, A. M. (2021). Pain assessment tool with electrodermal activity for postoperative patients: Method validation study. JMIR mHealth and uHealth, 9(5), Article e25258. https://doi.org/10.2196/25258

Camacho-Navas, C., Li, L., Poply, K., Mehta, V., & Kyriacou, P. A. (2026). Pain assessment using physiological responses/markers in different types of pain: A scoping review. npj Digital Medicine, 9, Article 64. https://doi.org/10.1038/s41746-025-02241-6

Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., Ding, X., Dunn, J., Elgendi, M., Ferdoushi, M., Franklin, D., Gil, E., Hassan, M. F., Hernesniemi, J., Hu, X., ... Zhu, T. (2023). The 2023 wearable photoplethysmography roadmap. Physiological Measurement, 44(11), Article 111001. https://doi.org/10.1088/1361-6579/acead2

Chen, Y., Tian, Y., Zhou, H., Xu, J., Zhao, C., Sun, Y., & Liu, H. (2025). Assessment and biomarker exploration of chronic pain using wearable EEG device. Discover Sensors, 1, Article 28. https://doi.org/10.1007/s44397-025-00030-0

Chow, H.-W., & Yang, C.-C. (2020). Accuracy of optical heart rate sensing technology in wearable fitness trackers for young and older adults: Validation and comparison study. JMIR mHealth and uHealth, 8(4), Article e14707. https://doi.org/10.2196/14707

De Brouwer, M., Vandenbussche, N., Steenwinckel, B., Stojchevska, M., Van Der Donckt, J., Degraeve, V., Vaneessen, J., De Turck, F., Volckaert, B., Boon, P., Paemeleire, K., Van Hoecke, S., & Ongenae, F. (2022). mBrain: Towards the continuous follow-up and headache classification of primary headache disorder patients. BMC Medical Informatics and Decision Making, 22(1), Article 87. https://doi.org/10.1186/s12911-022-01813-w

Domínguez, F., Heras, J., Benjumea, J., Vallejo, M., Parra, E., Fiallos, W., Villao, A., Pazmiño, F., Stiens, J., & da Silva, B. (2026). Evaluating a wearable-based pain monitoring system in palliative cancer care: Usability and feasibility study. JMIR Formative Research, 10, Article e78098. https://doi.org/10.2196/78098

Dudarev, V., Barral, O., Radaeva, M., Davis, G., & Enns, J. T. (2024). Night time heart rate predicts next-day pain in fibromyalgia and primary back pain. PAIN Reports, 9(2), Article e1119. https://doi.org/10.1097/PR9.0000000000001119

El-Tallawy, S. N., Pergolizzi, J. V., Vasiliu-Feltes, I., Ahmed, R. S., LeQuang, J. A., El-Tallawy, H. N., Varrassi, G., & Nagiub, M. S. (2024). Incorporation of artificial intelligence for objective pain assessment: A comprehensive review. Pain and Therapy, 13(3), 293–317. https://doi.org/10.1007/s40122-024-00584-8

Farmani, J., Bargshady, G., Gkikas, S., Tsiknakis, M., & Fernandez-Rojas, R. (2025). A CrossMod-Transformer deep learning framework for multi-modal pain detection through EDA and ECG fusion. Scientific Reports, 15(1), Article 29467. https://doi.org/10.1038/s41598-025-14238-y

Gamboa, P., Varandas, R., Mrotzeck, K., Plácido da Silva, H., & Quaresma, C. (2025). Electrodermal activity analysis at different body locations. Sensors, 25(6), Article 1762. https://doi.org/10.3390/s25061762

Gkikas, S., & Tsiknakis, M. (2023). Automatic assessment of pain based on deep learning methods: A systematic review. Computer Methods and Programs in Biomedicine, 231, Article 107365. https://doi.org/10.1016/j.cmpb.2023.107365

Gouverneur, P., Li, F., Shirahama, K., Luebke, L., Adamczyk, W. M., Szikszay, T. M., Luedtke, K., & Grzegorzek, M. (2023). Explainable artificial intelligence (XAI) in pain research: Understanding the role of electrodermal activity for automated pain recognition. Sensors, 23(4), Article 1959. https://doi.org/10.3390/s23041959

Gouverneur, P., Badura, A., Li, F., Bieńkowska, M., Luebke, L., Adamczyk, W. M., Szikszay, T. M., Myśliwiec, A., Luedtke, K., Grzegorzek, M., & Piętka, E. (2024). An experimental and clinical physiological signal dataset for automated pain recognition. Scientific Data, 11(1), Article 1051. https://doi.org/10.1038/s41597-024-03878-w

Gungormus, D. B., García-Moreno, F. M., Bermúdez-Edo, M., Sánchez-Bermejo, L., Garrido, J. L., Rodríguez-Fórtiz, M. J., & Pérez-Mármol, J. M. (2024). A semi-automatic mHealth system using wearable devices for identifying pain-related parameters in elderly individuals. International Journal of Medical Informatics, 184, Article 105371. https://doi.org/10.1016/j.ijmedinf.2024.105371

Hamilton, R. I., Alava Garcia, A., Bowd, J., Hamilton, D., Mason, D., Elliott, M., & Holt, C. (2024). Utilising electrodermal activity sensor signals to quantify nociceptive response during movement activities. BMC Research Notes, 17(1), Article 36. https://doi.org/10.1186/s13104-024-06689-9

Heros, R., Patterson, D., Huygen, F., Skaribas, I., Schultz, D., Wilson, D., Fishman, M., Falowski, S., Moore, G., Kallewaard, J. W., Dehghan, S., Kyani, A., & Mansouri, M. (2023). Objective wearable measures and subjective questionnaires for predicting response to neurostimulation in people with chronic pain. Bioelectronic Medicine, 9(1), Article 13. https://doi.org/10.1186/s42234-023-00115-4

Jang, E.-H., Eum, Y.-J., Yoon, D., & Byun, S. (2025). Classifying emotionally induced pain intensity using multimodal physiological signals and subjective ratings: A pilot study. Applied Sciences, 15(13), Article 7149. https://doi.org/10.3390/app15137149

Jiang, M., Li, Y., He, J., Yang, Y., Xie, H., & Chen, X. (2024). Physiological time-series fusion with hybrid attention for adaptive recognition of pain. IEEE Journal of Biomedical and Health Informatics, 28(11), 6865–6873. https://doi.org/10.1109/JBHI.2024.3456441

Johnson, A., Yang, F., Gollarahalli, S., Banerjee, T., Abrams, D., Jonassaint, J., Jonassaint, C., & Shah, N. (2019). Use of mobile health apps and wearable technology to assess changes and predict pain during treatment of acute pain in sickle cell disease: Feasibility study. JMIR mHealth and uHealth, 7(12), Article e13671. https://doi.org/10.2196/13671

Kapustynska, V., Abromavičius, V., Serackis, A., Andruškevičius, S., Ryliškienė, K., & Paulikas, Š. (2025). Advancing a generalizable model for migraine prediction: Analysis of filtering techniques on physiological signals. Technology and Health Care, 33(5), 2184–2193. https://doi.org/10.1177/09287329251332415

Khan, M. U., Chetty, G., Gkikas, S., Tsiknakis, M., Goecke, R., & Fernandez-Rojas, R. (2026). GIAFormer: A gradient-infused attention and transformer for pain assessment with EDA-fNIRS fusion. Information Fusion, 131, Article 104173. https://doi.org/10.1016/j.inffus.2026.104173

Kim, Y., Pyo, S., Lee, S., Park, C., & Song, S. (2025). Estimation of pressure pain in the lower limbs using electrodermal activity, tissue oxygen saturation, and heart rate variability. Sensors, 25(3), Article 680. https://doi.org/10.3390/s25030680

Kong, Y., Posada-Quintero, H. F., & Chon, K. H. (2021). Real-time high-level acute pain detection using a smartphone and a wrist-worn electrodermal activity sensor. Sensors, 21(12), Article 3956. https://doi.org/10.3390/s21123956

Kong, Y., Hossain, M. B., Peitzsch, A., Posada-Quintero, H. F., & Chon, K. H. (2024). Automatic motion artifact detection in electrodermal activity signals using 1D U-net architecture. Computers in Biology and Medicine, 182, Article 109139. https://doi.org/10.1016/j.compbiomed.2024.109139

Kong, Y., & Chon, K. H. (2024). Electrodermal activity in pain assessment and its clinical applications. Applied Physics Reviews, 11(3), Article 031316. https://doi.org/10.1063/5.0200395

Lu, Z., Ozek, B., & Kamarthi, S. (2023). Transformer encoder with multiscale deep learning for pain classification using physiological signals. Frontiers in Physiology, 14, Article 1294577. https://doi.org/10.3389/fphys.2023.1294577

Maity, A. K., Veeraraghavan, A., & Sabharwal, A. (2022). PPGMotion: Model-based detection of motion artifacts in photoplethysmography signals. Biomedical Signal Processing and Control, 75, Article 103632. https://doi.org/10.1016/j.bspc.2022.103632

Moens, M., Billet, B., Molenberghs, G., De Smedt, A., Pilitsis, J. G., De Vos, R., Hanssens, K., Billot, M., Roulaud, M., Rigoard, P., & Goudman, L. (2023). Heart rate variability is not suitable as a surrogate marker for pain intensity in patients with chronic pain. Pain, 164(8), 1741–1749. https://doi.org/10.1097/j.pain.0000000000002868

Morimoto, M., Nawari, A., Savic, R., & Marmor, M. (2024). Exploring the potential of a smart ring to predict postoperative pain outcomes in orthopedic surgery patients. Sensors, 24(15), Article 5024. https://doi.org/10.3390/s24155024

Park, S., Zheng, D., & Lee, U. (2025). A PPG signal dataset collected in semi-naturalistic settings using Galaxy Watch. Scientific Data, 12(1), Article 892. https://doi.org/10.1038/s41597-025-05152-z

Patterson, D. G., Wilson, D., Fishman, M. A., Moore, G., Skaribas, I., Heros, R., Dehghan, S., Ross, E., & Kyani, A. (2023). Objective wearable measures correlate with self-reported chronic pain levels in people with spinal cord stimulation systems. npj Digital Medicine, 6(1), Article 146. https://doi.org/10.1038/s41746-023-00892-x

Pinzon-Arenas, J. O., Kong, Y., Chon, K. H., & Posada-Quintero, H. F. (2023). Design and evaluation of deep learning models for continuous acute pain detection based on phasic electrodermal activity. IEEE Journal of Biomedical and Health Informatics, 27(9), 4250–4260. https://doi.org/10.1109/JBHI.2023.3291955

Pittara, M., Anastasiou, A., Andreou, K., Matsangidou, M., Panayides, A., Petkov, N., & Pattichis, C. S. (2025). Machine learning methods on BioVid heat pain database for pain intensity estimation. Scientific Reports, 15(1), Article 38173. https://doi.org/10.1038/s41598-025-21987-3

Posada-Quintero, H. F., & Chon, K. H. (2020). Innovations in electrodermal activity data collection and signal processing: A systematic review. Sensors, 20(2), Article 479. https://doi.org/10.3390/s20020479

Pouromran, F., Radhakrishnan, S., & Kamarthi, S. (2021). Exploration of physiological sensors, features, and machine learning models for pain intensity estimation. PLoS ONE, 16(7), Article e0254108. https://doi.org/10.1371/journal.pone.0254108

Rethlefsen, M. L., Kirtley, S., Waffenschmidt, S., Ayala, A. P., Moher, D., Page, M. J., Koffel, J. B., Blunt, H., Brigham, T., Chang, S. D., Clark, J., Conway, A., Couban, R., de Kock, S., Farrah, K., Fehrmann, P., Foster, M., Fowler, S. A., Glanville, J., ... Young, S. (2021). PRISMA-S: An extension to the PRISMA statement for reporting literature searches in systematic reviews. Systematic Reviews, 10(1), Article 39. https://doi.org/10.1186/s13643-020-01542-z

Rukavina, K., Staunton, J., Zinzalias, P., Krbot Skoric, M., Wu, K., Bannister, K., Rizos, A., & Chaudhuri, K. R. (2025). Wearable devices may aid the recognition of fluctuation-related pain in Parkinson’s disease: An exploratory, cross-sectional analysis of two prospective observational studies. PLoS ONE, 20(1), Article e0316563. https://doi.org/10.1371/journal.pone.0316563

Shafiei, S. B., Shadpour, S., Pangburn, B., Bentley-McLachlan, M., & de Leon-Casasola, O. (2025). Pain classification using functional near infrared spectroscopy and assessment of virtual reality effects in cancer pain management. Scientific Reports, 15(1), Article 8954. https://doi.org/10.1038/s41598-025-93678-y

Stojancic, R. S., Subramaniam, A., Vuong, C., Utkarsh, K., Golbasi, N., Fernandez, O., & Shah, N. (2023). Predicting pain in people with sickle cell disease in the day hospital using the commercial wearable Apple Watch: Feasibility study. JMIR Formative Research, 7, Article e45355. https://doi.org/10.2196/45355

Stubberud, A., Ingvaldsen, S. H., Brenner, E., Winnberg, I., Olsen, A., Bruvik Gravdahl, G., Matharu, M. S., Nachev, P., & Tronvik, E. (2023). Forecasting migraine with machine learning based on mobile phone diary and wearable data. Cephalalgia, 43(5), Article 03331024231169244. https://doi.org/10.1177/03331024231169244

Subramanian, A., Cao, R., Kasaeyan Naeini, E., Aqajari, S. A. H., Hughes, T. D., Calderon, M.-D., Zheng, K., Dutt, N., Liljeberg, P., Salanterä, S., Nelson, A. M., & Rahmani, A. M. (2025). Multimodal pain recognition in postoperative patients: Machine learning approach. JMIR Formative Research, 9, Article e67969. https://doi.org/10.2196/67969

Teel, E. F., Ocay, D. D., Blain-Moraes, S., & Ferland, C. E. (2022). Accurate classification of pain experiences using wearable electroencephalography in adolescents with and without chronic musculoskeletal pain. Frontiers in Pain Research, 3, Article 991793. https://doi.org/10.3389/fpain.2022.991793

Toktay, B., Orhan, İ. I., Yıldırım, E., Akbulut, F. P., & Catal, C. (2025). Multimodal insights into diverse pain experiences: PhysioPain dataset. Data in Brief, 62, Article 111992. https://doi.org/10.1016/j.dib.2025.111992

Umeda, M., & Okifuji, A. (2022). Prediction of pain responses to subsequent cold pressor test via baseline heart rate variability in healthy adults. European Journal of Pain, 26(8), 1811–1820. https://doi.org/10.1002/ejp.2007

Vuong, C., Utkarsh, K., Stojancic, R., Subramaniam, A., Fernandez, O., Banerjee, T., Abrams, D. M., Fijnvandraat, K., & Shah, N. (2023). Use of consumer wearables to monitor and predict pain in patients with sickle cell disease. Frontiers in Digital Health, 5, Article 1285207. https://doi.org/10.3389/fdgth.2023.1285207

Wang, H., Nienaber, S., Dinges, L., & Al-Hamadi, A. (2025). AI-based bi-modal fusion system for automated clinical pain monitoring. Computers in Biology and Medicine, 198, Article 111260. https://doi.org/10.1016/j.compbiomed.2025.111260

View article in other formats

CrossMark check

CrossMark logo

Published

2026-09-30

Issue

Section

Articles

How to Cite

Grubinskienė, A., & Katkevičius, A. (2026). Wearable physiological sensor fusion for pain episode detection: a review. New Trends in Computer Sciences, 4(1), 196–207. https://doi.org/10.3846/ntcs.2026.26721

Share