Investigation of flyback transformer flux leakage reduction ways
Abstract
Results of experimental investigation and design optimization of flyback transformer are presented. Aim of the work is to investigate experimentally the impact of the flyback transformer design on the flux leakage and maximal output power. It is difficult to evaluate the effect of the leakage flux mathematically because it depends on various factors: the position of the windings relative to each other; the position of the windings in the transformer; the distance between the winding. A multi-winding flyback transformer was used for experiments. Using the results of the experiments optimal design of the investigated flyback transformer was defined.Article in Lithuanian.
Flyback tipo transformatoriaus sklaidos srauto mažinimo tyrimas Santrauka Darbe pateikti flyback tipo impulsinio transformatoriaus eksperimentiniai tyrimai. Tyrimų tikslas – ištirti, nuo ko priklauso flyback tipo transformatoriaus magnetolaidžio sklaidos srauto (angl. leakage inductance) reiškiniai, kurie mažina tokio tipo transformatoriaus efektyvumą ir didžiausiąją darbinę galią. Matematiškai sunku įvertinti sklaidos magnetinio srauto reiškinį transformatoriaus magnetinėje sistemoje, nes jis priklauso nuo transformatoriaus apvijų tarpusavio išsidėstymo. Todėl eksperimentui atlikti panaudotas daugelio apvijų flyback tipo transformatorius, kuris ištirtas eksperimentiškai. Palyginus gautus eksperimentų rezultatus, nustatytas optimalus tirto flyback transformatoriaus darbo režimas ir optimalūs konstrukciniai parametrai.Reikšminiai žodžiai: flyback transformatorius, magnetinis sklaidos srautas, viršįtampiai, slopinimo grandinė.
Keywords:
flyback transformer, flux leakage, voltage spikes, flyback clamping circuit, power lossesHow to Cite
Bielskis, E., Šapurov, M., & Platakis, A. (2017). Investigation of flyback transformer flux leakage reduction ways. Mokslas – Lietuvos Ateitis Science – Future of Lithuania, 9(3), 312-317. https://doi.org/10.3846/mla.2017.1037
Share
License
Copyright (c) 2017 The Author(s). Published by Vilnius Gediminas Technical University.
This work is licensed under a Creative Commons Attribution 4.0 International License.
View article in other formats
Published
2017-07-04
Issue
Section
Article
Copyright
Copyright (c) 2017 The Author(s). Published by Vilnius Gediminas Technical University.
License
This work is licensed under a Creative Commons Attribution 4.0 International License.
How to Cite
Bielskis, E., Šapurov, M., & Platakis, A. (2017). Investigation of flyback transformer flux leakage reduction ways. Mokslas – Lietuvos Ateitis Science – Future of Lithuania, 9(3), 312-317. https://doi.org/10.3846/mla.2017.1037